Modular turbines could ease data center power constraints

Blake Scholl compares Boom's 42-megawatt turbines to blade servers, arguing smaller units improve redundancy and avoid water use.

The episode’s best minutes

Full analysis
  1. 2:56Boom uses vertical integration to speed up engineering4 min
  2. 7:52Modular turbines could ease data center power constraintsPro pick 6 min
  3. 23:38Boom plans to make single-crystal blades in a digital foundryPro pick 2 min
  4. 3 more moments in the full episode
“The dirty little secret is that most data center water usage isn't the server cooling, it's actually the turbine cooling.”
Blake Schollat 10:30 · MTS
10:30

Takeaways Pro pick

  1. A gigawatt would use 24 turbines, plus two for redundancy.
  2. Boom says its turbine needs no water for cooling.
  3. Hot weather can reduce conventional turbine capacity by 20–30%.

About this segment

Blake Scholl compares Boom's 42-megawatt turbines to blade servers, arguing smaller units improve redundancy and avoid water use. He explains how hot weather can cut conventional turbine output.

Blake Scholl

Blake Scholl is founder and CEO of Boom Supersonic.

Founded Boom Supersonic and led XB-1, the first independently developed jet to break the sound barrier.

  • Theo Jaffee, Host · Co-founder & host, MTS

    One of the first members of a16z's new media team; earlier hosted the Emergent Ventures-backed Theo Jaffee Podcast.

  • Sophia Dew, Host · Host, MTS

From “Traditional Aerospace Supply Chains Are Cooked | Blake Scholl”, Oct 23, 2026. Watch the full episode

Answers “Is there enough power for AI?” See all 61 answers

Transcript

Transcribed by machine (Whisper) from the episode’s audio, so a word may be off here and there.

  1. 8:00

    You guys designed this turbine for a specific use case. I know most people probably know you guys as the supersonic aircrafts, but what you mentioned and alluded to earlier is this also works for powering AI data centers. So tell me a little bit about the design behind this turbine and what are the use cases that it's intended for? Yeah, so this is a modular turbine. And from the context of a data center, it's like a blade server of energy.

  2. 8:26

    And so let me explain what I mean by that. So 25 years ago, Google figured out that you could make a faster, cheaper, more reliable search engine by having a large number of small computers instead of a small number of large computers. The original Google was like 10,000 Dell servers. And they were able to have a lot of reliability basically by stringing all of those together. You know, a few of them might crash every now and then, but there was redundancy, so it all worked.

  3. 8:54

    And in the energy world, Traditionally, the way large-scale power generation has been done is what people call frame turbines. And that's like a mainframe. It's even the same word. It's like a mainframe of energy. And so these things are like hundreds of megawatts. To install them is like a construction project. And so not only are they sold out, if you could even get one, it takes years to put in.

  4. 9:20

    And if you want to go build a data center that makes its own power, you need to go to some kind of redundancy, right? So like, think about like, you know, in computing, we'll have like N plus one arrays. All right, well, if these turbines are so big, N might be three. And so, you know, the N plus one is four. And we just bought like one third extra turbines in order to have some reliability. And, but if you go to a smaller size, you spend a lot less overhead for reliability.

  5. 9:49

    So like a gigawatt is 24 of our turbines. and maybe you add two more in plus two. So you've got great reliability and you've got 10% overhead rather than one third overhead. So it really saves on capital equipment. And when turbines are like the thing that limits scaling of data centers, it's nice not to like have extra turbines sitting around that you're not even using. And moreover, this, you know, so this solves kind of multiple layers of like the white hot AI infrastructure problems.

  6. 10:17

    You know, like number one is you just can't get power, right? Can't get power from the grid. So now you got to get turbines. can't get turbines without waiting for years or paying exorbitant prices to buy them on the secondary market. But then you also run into, the public's got concerns. If you're going to pull electricity from the grid, our electricity price is going to go up. What about water usage?

  7. 10:38

    The dirty little secret is that most data center water usage isn't the server cooling, it's actually the turbine cooling. And I can talk about technically why, but this turbine doesn't need a drop of water and it lets you make your own electricity. So it overcomes kind of the two biggest objections that communities have about data centers. And then the third thing is noise. And obviously we're going to make this an ultra quiet turbine.

  8. 11:04

    It's from the same team that made static boom go away entirely. So I'm pretty sure we can make a turbine quiet too. This is so fascinating. One, I didn't totally realize that a lot of the water it takes for data centers typically goes to cooling down turbines. I did kind of assume it went to servers. Okay, so what I'm hearing here, Yeah, I mean, I think the water objection is, like, mostly bullshit because, like, let's face it, water just falls from the sky.

  9. 11:28

    Yeah. And, like, a water shortage is really an infrastructure shortage. But, by the way, sometimes we have the infrastructure shortage. We haven't figured out how to collect enough rainwater and get it to the right places. So that's real. And, yeah, you can defend a data center by saying, hey, there's closed-loop cooling for the GPUs. But if you're building your own power plant and you're using sort of, you know, GE turbines as an example, they are based on 1970s subsonic jet engines.

  10. 12:00

    And so think about when you're flying United and you look out the window, it's cold, right? They're like, sometimes they're like ice crystals. So those engines are designed for a very cold environment, like minus 50. When you're going supersonic, it's the exact opposite. When you're going twice as fast, you get a lot of heat. And so the operating environment's actually plus 160. So, but you take that subsonic engine and you put it in a data center in Texas or Wyoming, you know on a hot day it's 110 degrees and the way these engines work is they're taking in outside air they're compressing it when you compress it it gets hot it's like if you're taking all the energy in a big volume and you're squeezing it to a small volume so it gets hot and then you have to add energy so you squirt in some natural gas and you burn it and now it's really hot and then you

  11. 12:48

    have to put it out the back of the engine through what's called a high pressure turbine and at that point, it can be like 3,000 degrees. And you get the most efficiency by being at the highest temperature. So the entire engine is designed to run at the thermal limit of the high-pressure turbine. I'm being ultra nerdy here, but this is how it works. And so if it's a hot day in order not to melt the turbine blades, the only thing you can do is pull the throttle back. And so if you run a GE turbine, and I'm not picking just on GE. Everyone's like this. GE, solar, everyone's turbines have this issue. If it's a hot day, the only thing you can do to not melt the turbine is either pull the throttle back or throw water at it. And usually people do both. And so you'll lose something like 20% generation capacity with water. You lose maybe 30% generation capacity

  12. 13:40

    waterless. And so again, now you're buying more turbine for the hot day. You're buying more and more turbine for redundancy. And there's just a lot of waste in that and we can make it go away. Super fascinating. What does this all mean for the future of the AI data center build out? Can you give me some timelines here?